HowTo - Resolve 3D finger positioning problems

HowTo - Resolve 3D finger positioning problems

I am not able to position finger properly inside the 3D sensor, how to resolve it?

If users are not able to position finger properly inside the 3D sensor, this could be caused by improper sensor calibration. You can resolve it by following below steps:

(1) Perform sensor calibration using ADMIN menu on the device

Calibration is available under 'Maintenance' 'Sensor calibration' (Firmware 2.xx) or under 'Configuration' 'Maintenance' 'More' 'LEDs calibration' (Firmware 1.xx).

During calibration please consider these instructions:

  1. If sun-flap is not installed, please cover the sensor hole to prevent external light entering inside sensor. The sensor hole can be covered by hand or small notebook/mobile.

  2. If sun-flap is installed, please open the sun-flap with a small object like screwdriver/pen (best is thin and black) and keep the sensor hole open during calibration

 

(2) If calibration does not solve the problem, please repeat the process one more time after re-powering the Terminal.

Procedure to re-power device safely:

  1. Shutdown the device using ADMIN pages (do not shut down by just cutting power!)

  2. Power-off the device and wait for 30 seconds

  3. Re-power the device: remove from power supply and connect again to start device

It is important that device is shutdown & re-powered and not just rebooted. A mere reboot will not help because it does not re-initialize the sensor module.


    • Related Articles

    • HowTo - Resolve 3D sensor errors

      The sensor in 3D AIR (Model 2012, former 3D TERMINAL) is not working stably and sensor runtime issues are reported regularly Solution If firmware is not able to load sensor at startup or report sensor run-time issues (error codes 42/412/414), it may ...
    • HowTo - 3D Sensor-Probleme beheben

      Der Sensor im 3D AIR (Modell 2012, ehemals 3D TERMINAL) arbeitet nicht stabil und es werden regelmässig 'sensor runtime' Fehlermeldungen angezeigt. Lösung Falls die Firmware den Sensor beim Start nicht korrekt laden kann oder einen Sensor runtime ...
    • FAQ - Device error code description

      Question How to interpret the error codes reported on device and resolve them? Answer The following table provides brief description of device error codes. Error code Description Resolution 0 No error. 1 General error. 42 Sensor image caching (sensor ...
    • HowTo - Resolve enrollment errors

      Symptom: Enrollments on device are not reflected on server and device reports 'Enrollment error occurred' (error 702) on info page. Solution Enrollment errors on device happen if data consistency got violated with new enrollment, e.g. because of ...
    • Video - How to replace sensor in 3D TERMINAL

      The following video explains step by step how to replace the sensor in TBS 3D TERMINAL. Please follow the steps carefully: